EICR & electrical testing.
Inspection and testing with a report you can act on, for landlords who have to have one, buyers who want one, and businesses that need to prove it.
- 4.9from 45 Google reviews
- NAPITregistered contractor
- Certifiedand notified to building control
Who needs an EICR.
- Landlords in England: at least every 5 years, and between tenancies is good practice
- Houses in multiple occupation, where the duties are tighter still
- Businesses, as part of maintaining a safe workplace installation
- Homeowners: generally recommended every 10 years, or when buying
- Anyone buying a property with an installation of unknown age
- Before and after major work, or where a fault keeps recurring
What you get.
- Visual inspection and dead and live testing of the installation
- Every circuit identified and recorded on a schedule of test results
- Observations coded C1, C2, C3 or FI, with plain-English explanation
- A clear satisfactory or unsatisfactory outcome, and why
- A quote for any remedial work, itemised so you can decide
- The report issued to you (and to your tenants or agent where needed)
- 01 Book We agree access and how long we need on site, and warn you about power interruptions.
- 02 Inspect & test Circuit by circuit, with the results recorded as we go.
- 03 Report You get the EICR with each observation coded and explained.
- 04 Remedy If anything is C1 or C2 we quote to put it right and re-issue as satisfactory.
“They replied quickly to my enquiry, was available and costed up the project. It was then all completed to a very high standard and I was really happy with the outcome (adding power sockets and lights to my garage). Second time I've used them before and will definitely be using again when required.”
How often do landlords need an EICR?
In England, private landlords must have the electrical installation inspected and tested at least every 5 years, give the report to tenants, and supply it to the local authority within 7 days if asked. Any C1, C2 or FI must be remedied within 28 days, or sooner if the report says so.
What do the codes mean?
C1 is danger present and needs action immediately. C2 is potentially dangerous and needs remedial work. C3 is improvement recommended and does not by itself make a report unsatisfactory. FI means further investigation is required.
How much does an EICR cost?
It depends on the number of circuits, the size of the property and how accessible the installation is.
Will the power be off?
Yes, for parts of the test. We will tell you roughly how long, and work around anything critical on site where we can.
You might also need.